Conveyor belt with IDEM SAFETY pull-wire or belt misalignment switch on site
FACHMANN/Brands/IDEM SAFETY

Every metre,
protected.

IDEM SAFETY is the British manufacturer of safety switches with the world's widest stainless steel range. It is the reference for conveyors: rope pull, belt alignment and limit switches for harsh conditions, including explosive atmospheres. Fachmann Electric is its local partner.

ISO 13849-1 · up to PLeISO 13850 · emergency stopIP69K · 316 stainless
The range · by function

Product range

Belt alignment
01

Belt alignment

Detect when the belt runs off track and warn before it rubs the structure, gets damaged or spills material.

  • Python Line: roller that touches the belt edge only if it drifts. Two contact blocks, one for warning and one for stop, with adjustable trip angle. Rollers of 35 x 120, 50 x 170 and 35 x 230 mm; cast or 316 stainless housing.
  • Miniature version for light conveyors, cast or stainless.
EN 620 · IEC 60947-5-1 · warning + stop
Rope pull
02

Rope pull

Emergency stop at any point along the conveyor, where a guard or a mushroom button every few metres is not possible.

  • Guardian Line: up to 50 m (GLM), 80 to 100 m (GLS) or 250 m (GLH, dual-head) with a single switch. Over 2 km of belt with fewer than 20 units.
  • Patented tensioner installed by one person that avoids frequent re-tensioning; rope break monitoring and two-colour LED visible from a distance.
  • Versions in IP69K stainless, for -40 °C, with OSSD outputs (Z-Range) and with auto reset.
ISO 13850 · IEC 60947-5-5 · up to PLe
Safety limit switches
03

Safety limit switches

Detect the position of guards, carriages, tables and lifts with positive-opening contacts.

  • HLM: cast body for heavy duty.
  • HLM-SS: 316 stainless, suitable for high-temperature washdown with detergent.
  • LSPS: IP67 plastic body, with 11 actuator heads.
IEC 60947-5-1 · EN 50041 · over 5 million cycles
IDEM SAFETY stainless steel devices
04

Explosive atmospheres

  • RFID with OSSD outputs: individual coding per sensor, PLe without a safety relay per sensor and up to 30 in series.
  • Hygiecode: magnetic coding, designed to EHEDG guidelines, for the splash zone and direct food contact. 316 stainless, IP69K.
  • Two-hand control: requires both hands away from the point of operation.
  • 3-position enabling switches: for working inside the guard in service mode.
ISO 13851 · IEC 60947-5-8
Networked solutions
05

Networked solutions

Bring doors, stops and safety signals onto the plant network without point-to-point wiring.

  • Door solutions and I/O stations with PROFINET/PROFIsafe or EtherNet/IP with CIP Safety.
PROFIsafe · CIP Safety
IDEM SAFETY stainless steel emergency stops
06

Safety monitoring relays

Solo versiones antideflagrantes.

  • Relays that bring any IDEM SAFETY switch to PLe, Cat. 4, with LED diagnostics.
  • Cast or stainless steel housing, up to 4 contacts.
  • Padlockable guard for maintenance, supplied pre-wired.
ISO 13850 · ATEX / IECEx · zonas 1, 2, 21, 22
Mando a dos manos
07

Mando a dos manos

  • TouchSafe station: IP65.
  • Pulsadores Zero Force: they detect the hand by proximity and need no force to operate.
  • 20 N mechanical push buttons.
  • Adjustable floor stand.
  • 260 and 550 mm spacing per ISO 13851.
  • 3-position enabling switches: for working inside the guarded area in service mode.
ISO 13851 · IEC 60947-5-8
Llave atrapada
08

Llave atrapada

They enforce the access sequence mechanically: the key that opens the guard cannot be in the control panel at the same time.

  • Trapped-key interlocking systems and RFID guard locking with trapped key.
ISO/TS 19837
Networked solutions
09

Networked solutions

They bring doors, stops and safety signals onto the plant network without point-to-point wiring.

  • Versions with delayed contacts for stop category 1.
ISO 13849-1 · PLe
Standards & certifications

Standards
standards

Levels covered: PLe (non-contact with OSSD, rope pull, relays), Ex d IIC T6 Gb and Ex tb IIIC T85 °C Db (explosive atmospheres), IP69K (316 stainless).

EN 620
Continuous handling equipment: safety requirements for belt conveyors.
IEC 60947-5-1
Electromechanical control circuit devices with positive-opening contacts.
IEC 60947-5-3
Proximity devices with defined behaviour under fault conditions.
IEC 60947-5-5
Electrical emergency stop devices with mechanical latching, including rope pull.
IEC 60947-5-8
Three-position enabling switches.
ISO 13850
Emergency stop function: principles for design.
ISO 13849-1
Safety-related parts of control systems: Performance Level (PL).
ISO 14119
Interlocking devices associated with guards: design and selection.
ISO/TS 19837
Trapped key interlocking systems: design and selection.
ISO 13851
Two-hand control devices.
EN 50041
Standard mounting dimensions for limit switches.
ATEX / IECEx
Certification of equipment for gas and dust explosive atmospheres.
EHEDG
Hygienic design guidelines for food industry equipment.
Manufacturer catalog

Need the detail
by part number?

The full IDEM SAFETY catalog is on the official site. Fachmann is your local support.

Full catalog on IDEM SAFETY.com
Sectors

Sectors where
we integrate it.

Broadest coverage in mining and food plants, where conveyors, washdown and dust define the choice of switch.

Tell us your application.

We help you size the right solution for your plant.

  • A team of experts handles your case
  • We assess the risk and the application before recommending
  • You get the right solution
Step 01 / 05

Let's start with the application

Which machine, process or installation do you need to solve? Five questions, no more.

Begin survey