Control panel interior with CABUR terminal blocks, 24 Vdc power supplies and marking
FACHMANN/Brands/CABUR

Connection
that lasts.

CABUR has been the Italian manufacturer of panel terminal blocks since 1952. Today it covers everything inside the panel: connection, 24 Vdc power, protection and identification of every wire, and adds solutions for photovoltaics. Fachmann Electric is its local partner.

IEC 60947-7-1 · terminalsATEX / IECEx · Ex ebUL 508 · power supplies
The range · by function

Product range

Screw terminal blocks
01

Screw terminal blocks

The classic panel connection, in every variant an industrial installation requires.

  • CBC · CBD series: feed-through, high-current and earth terminal blocks.
  • Special terminal blocks: disconnect, fuse, test and measurement, thermocouple and with electronic components.
  • ATEX and IECEx certification: versions for use in hazardous areas.
IEC 60947-7-1 · IEC 60947-7-2
Spring terminal blocks
02

Spring terminal blocks

Spring connection that does not loosen under vibration and needs no re-tightening.

  • HMM series: single, double and triple-level feed-through, earth, disconnect and fuse terminal blocks.
  • Ex i versions: terminal blocks identified for intrinsically safe circuits.
IEC 60947-7-1 · Ex i versions
Push-in terminal blocks
03

Push-in terminal blocks

The wire is inserted directly, tool-free: cuts wiring time by up to 75 % and allows one-handed wiring.

  • EFC series: feed-through, double and triple-level, disconnect, fuse and earth terminal blocks, with stainless steel spring.
  • Insulated coloured release button: protects the operator from contact with live parts.
  • ATEX and IECEx certification: protection mode Ex eb IIC Gb.
IEC 60947-7-1 · ATEX / IECEx · UL
Distribution and panel accessories
04

Distribution and panel accessories

Everything that completes the terminal block inside the panel.

  • QBLOK · POLM: distribution blocks.
  • Jumpers, end plates, end stops, DIN rails, separators and protective covers
DIN rail · distribution
Power supplies
05

Power supplies

24 Vdc DIN-rail power supplies, from light control to heavy loads.

  • CSL · XCSE · CSD · CSF · CSW · CSG series: single-phase, three-phase and 1-2-3 phase. They run from -20 to +50 °C at full load without derating.
  • Hiccup protection: delivers peak current to start heavy loads and cuts out if the overload persists.
  • Alarm contact: switches when the output drops 10 % (CSF, CSG and CSW series).
UL 508 · Class I Div. 2
UPS and redundancy
06

UPS and redundancy

Keep 24 Vdc up when the mains is lost or a power supply fails.

  • DC-UPS XCSU: uninterruptible supply with integrated battery charging, 10 to 40 A.
  • Redundancy modules: two supplies in parallel so the failure of one does not cut power.
  • DC/DC converters
24 Vdc · N+1
Electronic protection
07

Electronic protection

Protects each 24 Vdc circuit separately, instead of one breaker for the whole panel.

  • CEP: electronic overcurrent protection, programmable from 1 to 10 A in 1 A steps, with 3 trip curves (fast, medium and slow). 8 mm wide.
  • Remote on/off: via 24 V pulses, status LED and alarm contact.
  • EMI filters: single-phase and three-phase.
24 Vdc · 1 to 10 A · 3 curves
Industrial Ethernet switches
08

Industrial Ethernet switches

DIN-rail or panel mounting, plug-and-play installation.

  • SWE-T: unmanaged, 5 and 8 ports 10/100 Mbps, 12 to 36 Vdc or 10 to 24 Vac supply, -10 to +60 °C, metal housing.
  • SWE-F: unmanaged Fast Ethernet, 5, 8 and 16 ports, 12 to 48 Vdc supply, metal housing for demanding industrial environments.
EN 62368-1 · cUL · DIN rail
Signal conditioners and relays
09

Signal conditioners and relays

The interface between the field and the PLC.

  • Galvanic isolators and temperature converters: eliminate ground loops and convert PT100 or thermocouple to 4-20 mA.
  • NPN/PNP signal duplicators and inverters: DIN-rail Modbus converters.
  • Electromechanical and solid-state relay modules: and D-Sub and IDC interfaces.
4-20 mA · 0-10 V · Modbus
Energy transition
10

Energy transition

Connection and protection for photovoltaics and e-mobility.

  • ISL · ISA · ISB · ISM string boxes: combine and protect strings, with shunt trip or production monitoring.
  • LINE 4 solar connectors: compatible with the most common panels and inverters.
  • EV Smart Charger: charging stations for electric vehicles.
photovoltaics · e-mobility
Marking printers
11

Marking printers

Print panel identification in your own workshop, with MarKing Pro software.

  • SmartPrint Plus: thermal transfer, up to 100 markers in 6 seconds; prints markers for CABUR and other brands' terminal blocks, wires, push buttons and contactors.
  • SmartRoll Plus: 300 dpi roll labels, with touchscreen, for high volumes.
  • CaburJet: compact, maintenance-free inkjet printer.
thermal transfer · inkjet · 300 dpi
CABUR cable labels and identification markers
12

Markers and labels

Identification that stays legible after years inside the panel.

  • Markers: for CABUR and other brands' terminal blocks, wires, push buttons and contactors.
  • Adhesive labels: for equipment and panels, and manual numbering.
  • Tested: in salt spray, UV exposure, solvent vapours and alcohol cleaning.
EN ISO 9227 · EN ISO 4892-2
Standards & certifications

Standards
standards

Levels covered: Ex eb IIC Gb (push-in terminal blocks) and Class I Div. 2 (power supplies).

IEC 60947-7-1
Terminal blocks for copper conductors.
IEC 60947-7-2
Protective earth terminal blocks for copper conductors.
ATEX / IECEx
Certification of equipment for explosive atmospheres (EFC push-in terminal blocks, Ex eb).
UL 508
Industrial control equipment (certification of CABUR power supplies).
Class I Div. 2
Use in hazardous locations under the North American classification.
EN 62368-1
Safety of information and communication technology equipment (Ethernet switches).
EN ISO 9227
Salt spray corrosion test.
EN ISO 4892-2
Ageing by xenon-arc lamp exposure (UV).
Manufacturer catalog

Need the detail
by part number?

The full CABUR catalog is on the official site. Fachmann is your local support.

Full catalog on cabur.it
Solutions where it's used

Where CABUR
is the answer.

Sectors

Sectors where
we integrate it.

Present in every industrial panel; broadest coverage in renewables, packaging and data centers, where 24 Vdc continuity and solar-side connection define availability.

Tell us your application.

We help you size the right solution for your plant.

  • A team of experts handles your case
  • We assess the risk and the application before recommending
  • You get the right solution
Step 01 / 05

Let's start with the application

Which machine, process or installation do you need to solve? Five questions, no more.

Begin survey